  Datasheet File OCR Text:
  2013.05 industrial.panasonic.com/ac/e/ panasonic corporation 2013 ? ? asctb114e 201305-t automation controls catalog ordering information relay for control panel of 1c 15a, and 2c 10a hl relays rohs compliant features 1. compact high-capacity control relay in the same external dimensions as an hc relay, this compact power relay enables high-capacity control: 15 a for 1 form c, 10 a for 2 form c. 2. designed for high reliability high operational reliability is achieved by solder-less construction, in which all connections between lead wires and the contact springs and terminal plate are w elded. 3. various types provided in rich lineup. led indicator and diode type is also available. 4. the terminals are compatible with #187 series tab terminals. 5. sockets and terminal sockets are av ailable. typical applications 1. factory automation equipment and automotive devices 2. control panels, power supply equipment, molding equipment, machine tools, welding equipment, a gricultural equipment, etc. 3. of?e equipment, automatic vending machines, telecommunications equipment, disaster prevention equipment, copiers, measuring devices, medical equipment, amusement devices, etc. 4. all types of household appliance contact arrangement 1: 1 form c 2: 2 form c hl f surge absorber *d: with diode contact material f: agsno 2 type terminal arrangement h: l: hp: pl: htm: plug-in type plug-in type with led indication pc board type pc board type with led indication tm type nominal coil voltage ac dc 6, 12, 24, 48, 100 (100/110), 120 (110/120), 200 (200/220), 240 (220/240) v 6, 12, 24, 48, 100 (100/110) v notes: certified by c-ul, csa and t?v please inquire about tv approved products. *diode type is available. (dc coil plug-in type with led indication only)
panasonic corporation 2013 ? panasonic corporation automation controls buisiness division industrial.panasonic.com/ac/e/ hl ? asctb114e 201305-t types 1. plug-in type standard packing: carton: 20 pcs.; case: 200 pcs. 2. plug-in type (with led indication) standard packing: carton: 20 pcs.; case: 200 pcs. nominal coil v oltage 1 form c 2 form c part no. part no. 6v ac hl1-h-ac6v-f hl2-h-ac6v-f 12v ac hl1-h-ac12v-f hl2-h-ac12v-f 24v ac hl1-h-ac24v-f hl2-h-ac24v-f 48v ac hl1-h-ac48v-f hl2-h-ac48v-f 100/110v ac hl1-h-ac100v-f hl2-h-ac100v-f 110/120v ac hl1-h-ac120v-f hl2-h-ac120v-f 200/220v ac hl1-h-ac200v-f hl2-h-ac200v-f 220/240v ac hl1-h-ac240v-f hl2-h-ac240v-f 6v dc hl1-h-dc6v-f hl2-h-dc6v-f 12v dc hl1-h-dc12v-f hl2-h-dc12v-f 24v dc hl1-h-dc24v-f hl2-h-dc24v-f 48v dc hl1-h-dc48v-f hl2-h-dc48v-f 100/110v dc hl1-h-dc100v-f hl2-h-dc100v-f nominal coil v oltage 1 form c 2 form c part no. part no. 6v ac hl1-l-ac6v-f hl2-l-ac6v-f 12v ac hl1-l-ac12v-f hl2-l-ac12v-f 24v ac hl1-l-ac24v-f hl2-l-ac24v-f 48v ac hl1-l-ac48v-f hl2-l-ac48v-f 100/110v ac hl1-l-ac100v-f hl2-l-ac100v-f 110/120v ac hl1-l-ac120v-f hl2-l-ac120v-f 200/220v ac hl1-l-ac200v-f hl2-l-ac200v-f 220/240v ac hl1-l-ac240v-f hl2-l-ac240v-f 6v dc hl1-l-dc6v-f hl2-l-dc6v-f 12v dc hl1-l-dc12v-f hl2-l-dc12v-f 24v dc hl1-l-dc24v-f hl2-l-dc24v-f 48v dc hl1-l-dc48v-f hl2-l-dc48v-f 100/110v dc hl1-l-dc100v-f hl2-l-dc100v-f 3. plug-in type (with led indication and diode) standard packing: carton: 20 pcs.; case: 200 pcs. 4. pc board type standard packing: carton: 20 pcs.; case: 200 pcs. nominal coil v oltage 1 form c 2 form c part no. part no. 6v dc hl1-l-dc6v-d-f hl2-l-dc6v-d-f 12v dc hl1-l-dc12v-d-f hl2-l-dc12v-d-f 24v dc hl1-l-dc24v-d-f hl2-l-dc24v-d-f 48v dc hl1-l-dc48v-d-f hl2-l-dc48v-d-f 100/110v dc hl1-l-dc100v-d-f hl2-l-dc100v-d-f nominal coil v oltage 1 form c 2 form c part no. part no. 6v ac hl1-hp-ac6v-f hl2-hp-ac6v-f 12v ac hl1-hp-ac12v-f hl2-hp-ac12v-f 24v ac hl1-hp-ac24v-f hl2-hp-ac24v-f 48v ac hl1-hp-ac48v-f hl2-hp-ac48v-f 100/110v ac hl1-hp-ac100v-f hl2-hp-ac100v-f 110/120v ac hl1-hp-ac120v-f hl2-hp-ac120v-f 200/220v ac hl1-hp-ac200v-f hl2-hp-ac200v-f 220/240v ac hl1-hp-ac240v-f hl2-hp-ac240v-f 6v dc hl1-hp-dc6v-f hl2-hp-dc6v-f 12v dc hl1-hp-dc12v-f hl2-hp-dc12v-f 24v dc HL1-HP-DC24V-f hl2-hp-dc24v-f 48v dc hl1-hp-dc48v-f hl2-hp-dc48v-f 100/110v dc hl1-hp-dc100v-f hl2-hp-dc100v-f 5. pc board type (with led indication) standard packing: carton: 20 pcs.; case: 200 pcs. 6. tm type standard packing: carton: 20 pcs.; case: 200 pcs. nominal coil v oltage 1 form c 2 form c part no. part no. 6v ac hl1-pl-ac6v-f hl2-pl-ac6v-f 12v ac hl1-pl-ac12v-f hl2-pl-ac12v-f 24v ac hl1-pl-ac24v-f hl2-pl-ac24v-f 48v ac hl1-pl-ac48v-f hl2-pl-ac48v-f 100/110v ac hl1-pl-ac100v-f hl2-pl-ac100v-f 110/120v ac hl1-pl-ac120v-f hl2-pl-ac120v-f 200/220v ac hl1-pl-ac200v-f hl2-pl-ac200v-f 220/240v ac hl1-pl-ac240v-f hl2-pl-ac240v-f 6v dc hl1-pl-dc6v-f hl2-pl-dc6v-f 12v dc hl1-pl-dc12v-f hl2-pl-dc12v-f 24v dc hl1-pl-dc24v-f hl2-pl-dc24v-f 48v dc hl1-pl-dc48v-f hl2-pl-dc48v-f 100/110v dc hl1-pl-dc100v-f hl2-pl-dc100v-f nominal coil v oltage 1 form c 2 form c part no. part no. 6v ac hl1-htm-ac6v-f hl2-htm-ac6v-f 12v ac hl1-htm-ac12v-f hl2-htm-ac12v-f 24v ac hl1-htm-ac24v-f hl2-htm-ac24v-f 48v ac hl1-htm-ac48v-f hl2-htm-ac48v-f 100/110v ac hl1-htm-ac100v-f hl2-htm-ac100v-f 110/120v ac hl1-htm-ac120v-f hl2-htm-ac120v-f 200/220v ac hl1-htm-ac200v-f hl2-htm-ac200v-f 220/240v ac hl1-htm-ac240v-f hl2-htm-ac240v-f 6v dc hl1-htm-dc6v-f hl2-htm-dc6v-f 12v dc hl1-htm-dc12v-f hl2-htm-dc12v-f 24v dc hl1-htm-dc24v-f hl2-htm-dc24v-f 48v dc hl1-htm-dc48v-f hl2-htm-dc48v-f 100/110v dc hl1-htm-dc100v-f hl2-htm-dc100v-f
panasonic corporation 2013 ? panasonic corporation automation controls buisiness division industrial.panasonic.com/ac/e/ hl ? asctb114e 201305-t rating 1. coil data 1) ac coils notes: 1. the relay operates in a range of 80% to 110% v of the nominal voltage, but ideally, in consideration of temporary volta ge ?ctuations, it should be operated at the r ated voltage. in particular, for ac operation, if the applied voltage drops to 80% v or more below the nominal voltage, humming will occur an d a large current will ?w leading possibly to coil burnout. 2. the maximum applied voltage is the maximum voltage ?ctuation value for the coil power supply. this value is not a permissibl e value for continuous operation. (this value differs depending on the ambient temperature. please contact us for details.) 2) dc coils (at 20 c 68 f ) notes: 1. the nominal operating current is 10% (20 c 68 f ). 2. the coil resistance for dc operation is the value measured when the coil temperature is 20 c 68 f . compensate 0.4% for every 1 c change in temperature. 3. the relay operates in a range of 80% to 110% v of the nominal voltage, but ideally, in consideration of temporary voltage ?c tuations, it should be operated at the nominal voltage. 4. for use with 200 v dc, connect a 10 k ? (5w) resistor, in series, to the 100 v dc relay. 5. the maximum applied voltage is the maximum voltage ?ctuation value for the coil power supply. this value is not a permissibl e value for continuous operation. (this value differs depending on the ambient temperature. please contact us for details.) 2. speci?ations notes: if integrating into electrical appliances that will be subject to compliance to the electrical appliance and material saf ety law, please use in an ambient temperature between ?0 c to +40 c ?8 f to +104 f (ac type). *1. this value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it i s recommended to check this with the actual load. *2. for the ac coil types, the operate/release time will differ depending on the phase. *3. the upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. refe r to usage, transport and storage conditions in notes. *4. when using the socket, be sure to verify the max. continuous current. nominal coil v oltage nominal coil current (ma) nominal operating power (va) pick-up voltage (at 20 c 68 f ) drop-out voltage (at 20 c 68 f ) inductance (h) max. applied v oltage (at 70 c 158 f ) 50hz 60hz 50hz 60hz when drop-out when operating 6v ac 224 200 1.3 1.2 80%v or less of nominal voltage (initial) 30%v or more of nominal voltage (initial) 0.078 0.074 110%v of nominal voltage 12v ac 111 100 0.312 0.295 24v ac 56 50 1.243 1.181 48v ac 28 25 4.974 4.145 100/110v ac 13.4/14.7 12/13.2 23.75 20.63 110/120v ac 12.2/13.5 10.9/11.9 27.19 25.57 200/220v ac 6.7/7.4 6/6.6 85.98 81.76 nominal coil v oltage nominal coil current (ma) nominal operating power (w) coil resistance ( ? ) pick-up voltage (at 20 c 68 f ) drop-out voltage (at 20 c 68 f ) max. applied voltage (at 70 c 158 f ) 6v dc 150 0.9 40 80%v or less of nominal voltage (initial) 10%v or more of nominal voltage (initial) 110%v of nominal voltage 12v dc 75 160 24v dc 37 650 48v dc 18.5 2,600 100/110v dc 10 1.0 10,000 characteristics item speci?ations contact contact resistance (initial) max. 50 m ? (by voltage drop 6 v dc 1a) contact material agsno 2 type rating nominal switching capacity* 4 1 form c: 15a 125v ac, 10a 250v ac (resistive load) 2 form c: 10a 250v ac (resistive load) min. switching capacity (reference value)* 1 100ma 5v dc electrical characteristics insulation resistance (initial) min. 100m ? (at 500v dc) measurement at same location as ?reakdown voltage section. breakdown voltage (initial) between open contacts 1,000 vrms for 1min. (detection current: 10ma) between contact sets 1,500 vrms for 1min. (detection current: 10ma) between contact and coil 2,000 vrms for 1min. (detection current: 10ma) t emperature rise (coil) max. 80 c 176 f (by resistive method, nominal voltage) operate time (at 20 c 68 f )* 2 dc type/ac type: max. 25ms (nominal coil voltage applied to the coil, excluding contact bounce time.) release time (at 20 c 68 f )* 2 dc type/ac type: max. 25ms (nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode) mechanical characteristics shock resistance functional min. 196 m/s 2 (half-wave pulse of sine wave: 11 ms; detection time: 10 s.) destructive min. 980 m/s 2 (half-wave pulse of sine wave: 6 ms.) vibration resistance functional 10 to 55 hz at double amplitude of 1 mm (detection time: 10 s.) destructive 10 to 55 hz at double amplitude of 2 mm expected life mechanical ac type: 5 10 7 (at 180 times/min.), dc type: 10 8 (at 180 times/min.) electrical ac load 1 form c: 15a 125v ac, 10a 250v ac resistive load (cos ? =1) life switching cycle: min. 5 10 5 2 form c: 10a 250v ac resistive load (cos ? =1) life switching cycle: min. 3 10 5 dc load 1 form c: 3a 30v dc resistive load (cos ? =1) life switching cycle: min. 5 10 5 2 form c: 3a 30v dc resistive load (cos ? =1) life switching cycle: min. 5 10 5 conditions conditions for operation, transport and storage* 3 ambient temperature: ?0 c to +70 c ?8 f to +158 f (without led indication); ?0 c to +60 c ?8 f to +140 f (with led indication) humidity: 5 to 85% r.h. (not freezing and condensing at low temperature) max. operating speed 20 times/min. (at max. rating) unit weight approx. 35g 1.23 oz
panasonic corporation 2013 ? panasonic corporation automation controls buisiness division industrial.panasonic.com/ac/e/ hl ? asctb114e 201305-t reference data with diode type (for dc) dimensions (mm inch ) 1. plug-in type switching capacity range (1 form c) switching capacity range (2 form c) 100 500 1,000 10 10 15 1 0.1 dc inductive load (l/r=7ms) ac inductive load (cos ? =0.4) dc resistive load ac resistive load contact voltage, v contact current, a 100 500 1,000 10 10 1 0.1 ac resistive load contact current, a contact voltage, v dc inductive load (l/r=7ms) ac inductive load (cos ? =0.4) dc resistive load 1. dc coil surge voltage waveform (without diode) 2. dc coil surge voltage waveform (with diode) diode characteristics; reverse breakdown voltage: 1,000v, f orward current: 1a off on 260v 12v dc + to digital memory off on 12v dc + to digital memory ( ( reverse breakdown voltage: 1,000 v f orward current: 1 a the cad data of the products with a cad data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ 1 form c external dimensions 20.8 .819 35.4 1.394 6.35 .250 27.2 1.071 1.2 .047 2 3 6 78 10 .394 14.2 .559 3.75 4.6 6 7.15 .148 .181 .236 .281 compatible with tab terminal #187 series receptacle. 0.5 .020 general tolerance: 0.3 .012 schematic (bottom view) standard type with diode type 3 2 6 8 7 78 ( ? )( + ) 3 2 6 led ac type led dc type 8 7 ( ) ( ) 3 2 6 8 7 ( ? ) ( + ) 3 2 6 cad data
panasonic corporation 2013 ? panasonic corporation automation controls buisiness division industrial.panasonic.com/ac/e/ hl ? asctb114e 201305-t 2. pc board type 2 form c external dimensions 20.8 .819 35.4 1.394 6.35 .250 27.2 1.071 1.2 .047 1 2 4 3 5 6 78 3.7 4.7 6 7.3 .146 .185 .236 .287 10 .394 14.2 .559 0.5 .020 compatible with tab terminal #187 series receptacle. general tolerance: 0.3 .012 schematic (bottom view) standard type with diode type 34 12 56 8 7 78 ( ? )( + ) 3 1 5 4 2 6 led ac type led dc type 8 7 ( ) ( ) 34 12 56 8 7 ( ? ) ( + ) 34 12 56 cad data 1 form c external dimensions 20.8 .819 35.4 1.394 3.5 .138 5 .197 1.5 .059 2 3 6 78 10 .394 14.2 .559 3.75 4.6 6 7.15 .148 .181 .236 .281 27.2 1.071 1.2 .047 0.5 .020 general tolerance: 0.3 .012 schematic (bottom view) standard type 3 2 6 8 7 led ac type led dc type 8 7 ( ) ( ) 3 2 6 8 7 ( ? ) ( + ) 3 2 6 pc board pattern (bottom view) t olerance: 0.1 .004 5-.079 dia. 5-2 dia. hole 7.15 .281 .699 17.75 8.5 8.5 .335 14.2 .559 4.6 .181 6 .236 4 .157 10 .394 r.118 r3 r.079 r2 cad data
panasonic corporation 2013 ? panasonic corporation automation controls buisiness division industrial.panasonic.com/ac/e/ hl ? asctb114e 201305-t 3. tm type 2 form c external dimensions 20.8 .819 35.4 1.394 3.5 .138 5 .197 1.5 .059 10 .394 14.2 .559 3.7 4.7 6 7.3 .146 .185 .236 .287 1 2 4 3 5 6 78 27.2 1.071 1.2 .047 0.5 .020 general tolerance: 0.3 .012 schematic (bottom view) standard type 34 12 56 8 7 led ac type led dc type 8 7 ( ) ( ) 34 12 56 8 7 ( ? ) ( + ) 34 12 56 pc board pattern (bottom view) t olerance: 0.1 .004 8-.079 dia. 8-2 dia. hole 7.3 .287 .709 18 13.3 .524 14.2 .559 1.25 1.25 1.25 .049 .049 .049 2 4 .157 4 4 10 .394 2 .079 .079 r.079 r2 r2 r.079 cad data 1 form c external dimensions 20.6 .811 34.4 1.354 6.35 .250 2 3 6 78 37.6 1.480 .142 3.6 43 1.693 1.2 .047 2 .079 3.75 4.6 6 7.15 .148 .181 .236 .281 0.5 .020 compatible with tab terminal #187 series receptacle. general tolerance: 0.3 .012 schematic (bottom view) standard type 3 2 6 8 7 chassis (panel) cutout chassis (panel) cutout in tandem mounting 37.6 1.470 2-.126 to .138 dia. 2-3.2 to 3.5 dia. hole 21 23 .906 21 .827 .827 2 .079 37.6 1.470 t olerance: 0.1 .004 notes: 1. if connecting to #187 series tab terminals, use amp faston #187 series or #187 tab terminals conforming to ul or csa inch-standard dimensions. 2. in mounting, use m3 screws and m3 washers. 3. when mounting tm types, use washers to prevent damage or distortion to the polycarbonate cover. 4. when tightening ?ing screws, the optimum torque range should be 0.294 to 0.49 n?, (3 to 5 kgf?m). moreover, use w ashers to prevent loosening. cad data
panasonic corporation 2013 ? panasonic corporation automation controls buisiness division industrial.panasonic.com/ac/e/ hl ? asctb114e 201305-t safety standards 1. standard type (plug-in type except with diode, pc board type, tm type) 2. plug-in type (with diode)* 2 note: ?1 indicates the ul/c-ul recognition ?e number. ?2 dc coil plug-in type with led indication only. contact arrangement ul/c-ul (recognized) csa (certi?d) tv rating (ul/csa) t?v rating file no. contact rating file no. contact rating file no. rating file no. rating 1 form c e43028* 1 15a 250v ac 1 / 3 hp 125, 250v ac 10a 30v dc lr26550 etc. 10a 125, 250v ac 1 / 3 hp 125, 250v ac 10a 30v dc ul: e43149 csa: lr26550 etc. no ? tv-5 nc ? tv-2 b1304 13461 340 15a 125v~ (cos =1.0) 10a 250v~ (cos =1.0) 10a 30v (l/r=0ms) 2 form c e43028* 1 10a 250v ac 1 / 3 hp 125, 250v ac 10a 30v dc lr26550 etc. 10a 125, 250v ac 1 / 3 hp 125, 250v ac 10a 30v dc ul: e43149 csa: lr26550 etc. no ? tv-4 nc ? tv-2 b1304 13461 340 10a 250v~ (cos =1.0) 10a 30v (l/r=0ms) contact arrangement ul/c-ul (recognized) csa (certi?d) tv rating (ul/csa) t?v rating file no. contact rating file no. contact rating file no. rating file no. rating 1 form c e43028* 1 15a 250v ac 1 / 3 hp 125, 250v ac 10a 30v dc csa standard certi?d by c-ul b1304 13461 340 15a 125v~ (cos =1.0) 10a 250v~ (cos =1.0) 10a 30v (l/r=0ms) 2 form c e43028* 1 10a 250v ac 1 / 3 hp 125, 250v ac 10a 30v dc csa standard certi?d by c-ul b1304 13461 340 10a 250v~ (cos =1.0) 10a 30v (l/r=0ms) 2 form c external dimensions 20.6 .811 34.4 1.354 6.35 .250 43 1.693 1.2 .047 2 .079 1 2 4 3 5 6 78 37.6 1.480 .142 3.6 3.7 4.7 6 7.3 .146 .185 .236 .287 0.5 .020 compatible with tab terminal #187 series receptacle. general tolerance: 0.3 .012 schematic (bottom view) standard type 34 12 56 8 7 chassis (panel) cutout chassis (panel) cutout in tandem mounting 37.6 1.470 2-.126 to .138 dia. 2-3.2 to 3.5 dia. hole 21 23 .906 21 .827 .827 2 .079 37.6 1.470 t olerance: 0.1 .004 notes: 1. if connecting to #187 series tab terminals, use amp faston #187 series or #187 tab terminals conforming to ul or csa inch-standard dimensions. 2. in mounting, use m3 screws and m3 washers. 3. when mounting tm types, use washers to prevent damage or distortion to the polycarbonate cover. 4. when tightening ?ing screws, the optimum torque range should be 0.294 to 0.49 n?, (3 to 5 kgf?m). moreover, use w ashers to prevent loosening. cad data


▲Up To Search▲   

 
Price & Availability of HL1-HP-DC24V

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X